Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Spark Igniter for RGS180SFAA0AAAA — OEM Sparker | Ships Today
ICP

ICP Spark Igniter for RGS180SFAA0AAAA — OEM Sparker | Ships Today

SKU: 1184216 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM spark igniter (part number 1184216) provides the high-voltage spark that lights the burners in ICP Tempstar Heil RGS-series gas furnaces. On a call for heat, the control board energizes the igniter, which arcs across its electrode gap to ignite the gas at the pilot or burner. A worn, cracked, or fouled igniter is a leading cause of intermittent or failed ignition. Common symptoms include a furnace that clicks repeatedly but never lights, delayed ignition with a small whoosh, soot or corrosion on the electrode tip, or repeated lockouts after several failed ignition attempts. Replacing the sparker restores reliable, on-demand ignition and prevents nuisance no-heat calls.

Specifications

Spec Value
Part Number 1184216
Type Spark Igniter / Sparker
Brand ICP (Tempstar / Heil)
Function Direct-spark / pilot ignition
Fitment OEM

Compatibility

Designed as a direct-fit replacement for ICP Tempstar Heil model RGS180SFAA0AAAA and related RGS180-series gas furnaces. As the original equipment manufacturer igniter, it matches the factory electrode gap, mounting bracket, and lead connector, so no adjustment or adapters are required.

Installation Guide

  1. Safety First — Shut off gas, disconnect electrical power, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter position, gap, and wiring before removal.
  4. Remove — Disconnect the igniter lead, unscrew the igniter bracket, and carefully withdraw the old sparker without touching the ceramic.
  5. Install — Mount the new igniter, handling it by the bracket only, and reconnect the lead.
  6. Test — Restore gas and power, then run a heat cycle and confirm a strong, consistent spark and prompt burner ignition.

Signs You Need a Replacement

  • Furnace clicks repeatedly but burners never light.
  • Delayed ignition or a noticeable whoosh at startup.
  • Soot, cracks, or corrosion on the electrode tip.
  • Repeated ignition lockouts after failed attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180SFAA0AAAA — OEM Sparker | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180SFAA0AAAA — OEM Sparker | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180SFAA0AAAA — OEM Sparker | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.