Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Spark Igniter for RGS180LTCA0AAAA — OEM 1184216 Direct Spark Ignitor | Ships Today
ICP

ICP Spark Igniter for RGS180LTCA0AAAA — OEM 1184216 Direct Spark Ignitor | Ships Today

SKU: 1184216 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM spark igniter (part number 1184216) is the factory-specified ignition sparker for the ICP / Tempstar / Heil RGS180LTCA0AAAA gas furnace. A spark igniter generates the high-voltage arc that lights the burner gas at the start of every heat cycle and, on many designs, also confirms flame through the same electrode. Because it endures repeated high-voltage arcing and direct flame exposure, the electrode and ceramic insulator degrade over time — a worn igniter is a leading cause of failed ignition and no-heat lockouts.

Specifications

Spec Value
Part Number 1184216
Type Spark Igniter / Direct Spark Ignitor
Brand ICP (Tempstar / Heil)
Function Burner ignition (high-voltage spark)
Fit OEM direct replacement

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil RGS180LTCA0AAAA furnace. Match the bracket shape, electrode geometry, and lead connector to your original igniter to ensure correct spark gap and flame alignment.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position, spark gap, and lead routing before disconnecting.
  4. Remove — Unplug the ignition lead, remove the mounting screw(s), and lift the old igniter out of the burner assembly.
  5. Install — Set the new igniter so the electrode aligns with the burner port, fasten it, and reconnect the high-voltage lead per your photo.
  6. Test — Restore gas and power, call for heat, and confirm a strong spark and reliable burner light-off with no lockouts.

Signs You Need a Replacement

  • Furnace clicks but won't light, or locks out on failed ignition
  • Weak, intermittent, or no visible spark at the electrode
  • Cracked ceramic insulator or eroded electrode tip
  • Repeated ignition retries before the burner finally lights

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180LTCA0AAAA — OEM 1184216 Direct Spark Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180LTCA0AAAA — OEM 1184216 Direct Spark Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180LTCA0AAAA — OEM 1184216 Direct Spark Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online