Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Spark Igniter for RGS180HTAA0AAAA — Direct Spark Ignitor | Ships Today
ICP

ICP Spark Igniter for RGS180HTAA0AAAA — Direct Spark Ignitor | Ships Today

SKU: 1184216 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM spark igniter (sparker), part 1184216, fits the ICP/Heil/Tempstar RGS180HTAA0AAAA gas furnace. The igniter generates the high-voltage spark that lights the burner gas at the start of each heating cycle. Over time the electrode tip erodes and the ceramic insulator cracks, leading to weak, intermittent, or no ignition. Common failure symptoms include a furnace that clicks repeatedly but never lights, delayed ignition with a noticeable 'whoomp,' lockout after several failed trials, or no spark at all. Replacing a worn igniter restores fast, reliable lightoff and prevents nuisance lockouts on cold mornings.

Specifications

Spec Value
Part Number 1184216
Type Spark Igniter / Sparker
Brand ICP / Heil / Tempstar
Ignition Method Direct Spark
Fitment OEM

Compatibility

Fits the ICP/Heil/Tempstar RGS180HTAA0AAAA and shared-platform Comfortmaker furnaces using the same burner and ignition assembly. Confirm part 1184216 against your existing igniter before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power, then verify zero voltage at the control board with a multimeter.
  2. Access — Remove the furnace burner/service panel.
  3. Document — Photograph the igniter position, gap, and wire routing before removal.
  4. Remove — Disconnect the igniter lead and unscrew the igniter from the burner assembly, handling the ceramic by the body only.
  5. Install — Mount the new igniter at the correct gap and position, then reconnect the lead per your photo.
  6. Test — Restore gas and power and confirm a strong, immediate spark and clean burner lightoff.

Signs You Need a Replacement

  • Repeated clicking with no flame
  • Delayed ignition or rough lightoff
  • Cracked ceramic insulator or eroded electrode tip
  • Control lockout after failed ignition trials

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180HTAA0AAAA — Direct Spark Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180HTAA0AAAA — Direct Spark Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180HTAA0AAAA — Direct Spark Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online