Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Spark Igniter for RGS180HRAA0AAAA — Direct Spark Ignitor | Ships Today
ICP

ICP Spark Igniter for RGS180HRAA0AAAA — Direct Spark Ignitor | Ships Today

SKU: 1184216 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM spark igniter (part #1184216, IGNITOR SPARKER) is the ignition component for the ICP / Tempstar / Heil RGS180HRAA0AAAA furnace. On a direct-spark ignition system, this igniter generates a high-voltage spark at the burner to light the gas during each heat call. The igniter's electrode and ceramic insulator are exposed to repeated heating, flame, and combustion byproducts, so over time the tip erodes, cracks, or fouls — leading to weak or missing spark, delayed ignition, repeated ignition lockouts, or no heat. Replacing a worn igniter restores fast, consistent burner light-off and reduces nuisance lockouts on cold mornings.

Specifications

Spec Value
Part Number 1184216
Type Spark Igniter (Direct Spark)
Brand ICP (Tempstar / Heil)
Application Gas Furnace Burner Ignition
Insulator Ceramic
Fit OEM

Compatibility

Designed for the ICP RGS180HRAA0AAAA and compatible Tempstar, Heil, Comfortmaker, and ICP-family gas furnaces using a spark ignition system. Confirm your furnace uses a spark igniter (not a hot surface igniter) before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner / control compartment panel.
  3. Document — Photograph the igniter position, gap, and wiring before removal.
  4. Remove — Disconnect the igniter lead and unscrew the igniter from the burner assembly, handling the ceramic carefully.
  5. Install — Mount the new igniter at the correct gap and position, then reconnect the lead.
  6. Test — Restore gas and power and confirm a strong spark and reliable burner ignition.

Signs You Need a Replacement

  • Weak, intermittent, or no spark at the burner
  • Repeated ignition lockouts or delayed ignition
  • Cracked ceramic insulator or eroded electrode tip
  • Furnace runs the inducer but never lights

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180HRAA0AAAA — Direct Spark Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180HRAA0AAAA — Direct Spark Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180HRAA0AAAA — Direct Spark Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online