Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Spark Igniter for RGS180HEEA0AAAA — Direct Spark Ignition | Ships Today
ICP

ICP Spark Igniter for RGS180HEEA0AAAA — Direct Spark Ignition | Ships Today

SKU: 1184216 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM spark igniter (OEM 1184216, "Ignitor Sparker") is the direct-spark ignition electrode that lights the burners on your ICP / Tempstar / Heil RGS180HEEA0AAAA gas furnace. On each call for heat, the control board sends high voltage to the igniter, which produces a spark across its electrode gap to ignite the gas at the burner. A cracked ceramic insulator, eroded electrode tip, or carbon-fouled gap will cause weak or no spark, leading to ignition lockout and no heat. Replacing a worn spark igniter restores fast, reliable burner light-off.

Specifications

Spec Value
OEM Part Number 1184216
Type Direct Spark Igniter / Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Fit OEM Replacement

Compatibility

Designed as the factory ignition component for the ICP / Tempstar / Heil RGS180HEEA0AAAA and matching RGS180-series furnaces that use a direct spark ignition system.

Installation Guide

  1. Safety First — Shut off gas and disconnect power; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner compartment door.
  3. Document — Photograph the igniter position, electrode gap, and high-voltage lead routing.
  4. Remove — Disconnect the ignition lead and unscrew the igniter bracket from the burner assembly.
  5. Install — Mount the new spark igniter, set it at the manufacturer-specified gap over the burner, and reconnect the lead.
  6. Test — Restore gas and power, then verify a strong, consistent spark and clean burner ignition.

Signs You Need a Replacement

  • Weak, intermittent, or no spark at the burner
  • Furnace locks out after several failed ignition attempts
  • Cracked or chipped ceramic insulator on the electrode
  • Carbon buildup or erosion at the electrode tip

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180HEEA0AAAA — Direct Spark Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180HEEA0AAAA — Direct Spark Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180HEEA0AAAA — Direct Spark Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online