Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Spark Igniter for RGS180HDEA0AAAA — Direct Spark Ignitor OEM | Ships Today
ICP

ICP Spark Igniter for RGS180HDEA0AAAA — Direct Spark Ignitor OEM | Ships Today

SKU: 1184216 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM spark igniter / sparker electrode (part number 1184216) for the ICP / Tempstar / Heil RGS180HDEA0AAAA gas furnace. On a direct-spark ignition system, this electrode generates the high-voltage spark that lights the burner gas at the start of each heat cycle, and on many designs the same or a paired rod also senses the resulting flame. A cracked ceramic insulator, eroded electrode tip, or carbon-fouled gap will cause weak or no spark, failed ignition lockouts, delayed light-off with a rollout puff, or short cycling on a flame-sense fault. Replacing a worn sparker restores reliable, on-demand ignition.

Specifications

Spec Value
Part Number 1184216
Type Direct Spark Igniter / Sparker
Function High-voltage spark ignition electrode
Brand ICP / Tempstar / Heil
Fitment OEM Replacement

Compatibility

Direct OEM fit for the ICP family RGS180HDEA0AAAA gas furnace and related ICP, Tempstar, Heil, and Comfortmaker spark-ignition furnaces using the 1184216 sparker. Confirm the printed part number and bracket geometry on your existing igniter before ordering.

Installation Guide

  1. Safety First — Shut off gas, disconnect power, and verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment door.
  3. Document — Photograph the igniter position, gap, and the high-voltage lead routing.
  4. Remove — Unplug the ignition lead, unscrew the old sparker bracket, and lift it clear of the burner.
  5. Install — Mount the new igniter, set the spark gap per spec, and reconnect the high-voltage lead.
  6. Test — Restore gas and power and run a heat cycle to confirm a strong spark and prompt, stable burner light-off.

Signs You Need a Replacement

  • No spark or weak, intermittent spark
  • Furnace locks out on failed ignition
  • Cracked ceramic insulator or eroded electrode tip
  • Delayed ignition with a rollout puff or short cycling

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180HDEA0AAAA — Direct Spark Ignitor OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180HDEA0AAAA — Direct Spark Ignitor OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180HDEA0AAAA — Direct Spark Ignitor OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online