Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Spark Igniter Electrode for RGS244HSEA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Spark Igniter Electrode for RGS244HSEA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM igniter electrode (part number 1179966) for the ICP Tempstar/Heil RGS244HSEA0AAAA gas furnace. The igniter electrode initiates the burner flame at the start of every heat cycle; over time the ceramic insulator cracks, the electrode tip erodes, or carbon buildup prevents a reliable spark or surface ignition. A failed igniter is one of the most common no-heat causes, typically showing as an ignition lockout after several failed lightoff attempts. Genuine OEM construction ensures the correct gap, position, and high-temperature rating.

Specifications

Spec Value
Part Number 1179966
Type Ignition Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Fits Model RGS244HSEA0AAAA
Fitment OEM Replacement

Compatibility

Direct OEM replacement for the igniter electrode in the ICP Tempstar/Heil RGS244HSEA0AAAA. Compare the bracket shape, electrode length, and connector to your existing 1179966 before installing to ensure proper flame alignment.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas supply, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter's mounting position and wire routing before removing.
  4. Remove — Disconnect the ignition lead and unscrew the igniter bracket, handling the ceramic by the base only.
  5. Install — Mount the new 1179966 electrode at the correct gap and position, then reconnect the ignition lead.
  6. Test — Restore gas and power and confirm a clean lightoff and stable flame on a heat call.

Signs You Need a Replacement

  • Furnace locks out after repeated failed ignition attempts.
  • Cracked or chipped ceramic insulator.
  • No spark or weak, intermittent ignition.
  • Visible erosion or heavy carbon buildup on the electrode tip.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS244HSEA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS244HSEA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS244HSEA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online