This is a genuine OEM single-pole definite purpose contactor (part number 1050839) for the ICP Tempstar Heil YJ042GB1 heat pump. The contactor is an electrically operated switch that energizes the compressor and condenser fan motor when the thermostat calls for cooling or heating. It carries a 35-amp resistive rating across a single pole and is controlled by a 24-volt coil. When the contactor fails, the outdoor unit will not start, will chatter, or will weld closed and run continuously. Pitted, burned, or buzzing contacts are the most common reason a condensing unit stops responding to the thermostat.

Specifications

Spec Value
Part Number 1050839
Type Single-Pole (1P) Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Contact Rating 35A
Coil Voltage 24V
Poles 1

Compatibility

Designed as the factory replacement contactor for the ICP/Tempstar/Heil YJ042GB1 heat pump and other condensing units in the same family that use a 35A 24V single-pole control. Always confirm the contactor amperage and coil voltage against the part you are removing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit's electrical service panel.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Note the line, load, and 24V coil terminals, transfer wires one at a time, then unbolt the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to match your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor and fan start on a thermostat call.

Signs You Need a Replacement

  • Outdoor unit will not start even though the thermostat is calling
  • Loud buzzing or chattering from the contactor
  • Pitted, burned, or melted contact points
  • Compressor runs nonstop because contacts are welded closed

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YJ042GB1 — 35A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YJ042GB1 — 35A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YJ042GB1 — 35A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.