ICP Single-Pole Contactor for YG030GC2 — 25A 24V Coil | Ships Today
ICP

ICP Single-Pole Contactor for YG030GC2 — 25A 24V Coil | Ships Today

SKU: 1050699 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole definite purpose contactor (part number 1050699) switches line voltage to the compressor and condenser fan motor in your ICP / Tempstar / Heil YG030GC2 heat pump. On a thermostat call, the 24-volt control circuit energizes the contactor coil, closing the contacts and powering the outdoor unit. Rated at 25 amps with a 24V coil, it is engineered to withstand the high inrush current of compressor startup. Common failure symptoms include an outdoor unit that won't run, a buzzing or chattering contactor, pitted or welded contacts, and a coil that hums but won't pull the contacts in.

Specifications

Spec Value
Part Number 1050699
Type Single-Pole (1P) Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Current Rating 25 Amps
Coil Voltage 24V
Application AC Compressor / Heat Pump / Condenser Fan

Compatibility

Direct OEM replacement for the contactor in the ICP Tempstar Heil YG030GC2 heat pump. This 1-pole 25A 24V contactor is widely used across ICP-family residential condensing units and heat pumps sharing the same control voltage and amperage. Confirm the coil voltage (24V) and amp rating match your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and the breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel from the condensing unit.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil wires; unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Outdoor unit fails to start while the indoor blower runs
  • Loud buzzing, humming, or chattering from the contactor
  • Visibly pitted, burned, or welded-shut contacts
  • Coil energizes but contacts won't pull in or release

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YG030GC2 — 25A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YG030GC2 — 25A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YG030GC2 — 25A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.