This genuine OEM single-pole contactor (part number 1172472) is the direct replacement for the ICP / Tempstar / Heil WPG4304060RKA1. A contactor is the high-voltage switch that powers the compressor and condenser fan. When the thermostat calls for cooling, the 24-volt control circuit energizes the contactor coil, which pulls the contacts closed and sends line voltage to the load. This unit is rated 30 amps with a 24V coil and includes the integrated shunt. Contactors are among the most common HVAC failure points: their contacts arc and pit with every cycle, and over thousands of cycles they can weld shut (so the unit never stops) or burn open (so it never starts). A pitted or chattering contactor causes hard starts, buzzing, and erratic operation that stresses the compressor.

Specifications

Spec Value
OEM Part Number 1172472
Type Single-Pole (1P) Contactor
Contact Rating 30 Amps
Coil Voltage 24V
Feature Includes Shunt
Brand ICP / Tempstar / Heil

Compatibility

Direct-fit for the ICP WPG4304060RKA1 and the Tempstar, Heil, and Comfortmaker units built on the same platform. Confirm pole count, amp rating, and 24V coil against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel.
  3. Document — Photograph all line, load, and coil wires before disconnecting.
  4. Remove — Unscrew the mounting screws and transfer wires one at a time, or label each lead before removal.
  5. Install — Mount the new contactor and reconnect each wire to its matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly with no chatter when the system calls.

Signs You Need a Replacement

  • Buzzing or chattering from the contactor.
  • Compressor won't start or won't shut off.
  • Visibly pitted, burned, or melted contacts.
  • Coil tests open or won't pull the contacts in.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG4304060RKA1 — 30A 24V w/ Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG4304060RKA1 — 30A 24V w/ Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG4304060RKA1 — 30A 24V w/ Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.