Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Single-Pole Contactor for WCH3364GKA2 — 30A 24V w/Shunt | Ships Today
ICP

ICP Single-Pole Contactor for WCH3364GKA2 — 30A 24V w/Shunt | Ships Today

SKU: 1172472 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole definite purpose contactor (part number 1172472) is the electrically-controlled switch that energizes the compressor and condenser fan motor in your ICP Tempstar Heil WCH3364GKA2 heat pump. Rated at 30 amps with a 24-volt holding coil and an integrated shunt, it closes its line-voltage contacts whenever the thermostat calls for cooling or heating. A worn contactor is one of the most common causes of an outdoor unit that won't start, hums without engaging, or short-cycles. Pitted, burned, or welded contacts cause chattering, dropped voltage to the compressor, and tripped breakers.

Specifications

Spec Value
OEM Part Number 1172472
Type Single-Pole (1P) Definite Purpose Contactor w/Shunt
Brand ICP / Tempstar / Heil / Comfortmaker
Contact Rating 30 Amps
Coil Voltage 24V
Poles 1
Fitment OEM Replacement

Compatibility

Engineered as the direct OEM replacement for the ICP/Tempstar/Heil/Comfortmaker WCH3364GKA2 heat pump condensing unit. The same 30A/24V single-pole platform is shared across many ICP-family WCH-series outdoor units — verify the existing contactor's amp rating, coil voltage, and pole count against your old part before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and the main breaker. Verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the condensing unit's electrical access panel.
  3. Document — Photograph every wire and terminal location before disconnecting anything.
  4. Remove — Note the line, load, and 24V coil leads, then transfer wires one at a time. Unscrew the contactor from its mounting bracket.
  5. Install — Mount the new contactor, reconnect each wire exactly per your photo, confirming the 24V leads land on the coil terminals.
  6. Test — Restore power and call for cooling. Confirm the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but the compressor and fan won't start
  • Visibly pitted, burned, or welded contacts
  • Chattering or rapid clicking at the contactor
  • Compressor short-cycling or tripping the breaker

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH3364GKA2 — 30A 24V w/Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH3364GKA2 — 30A 24V w/Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH3364GKA2 — 30A 24V w/Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online