Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Single-Pole 30A Contactor for WJA330000K000A1 — 24V Coil with Shunt | Ships Today
ICP

ICP Single-Pole 30A Contactor for WJA330000K000A1 — 24V Coil with Shunt | Ships Today

SKU: 1172472 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole contactor (part number 1172472) is the primary switching relay for the ICP WJA330000K000A1 condensing unit. Rated at 30 amps with a 24-volt control coil and an integrated shunt, it energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. The coil pulls in a magnetic armature that closes the line-voltage contacts, delivering power to the high-voltage components. When the contacts pit, burn, or weld from the constant arcing of normal cycling, the unit will fail to start, chatter, or stay locked on even after the thermostat is satisfied. A failed contactor is one of the most common no-cool service calls.

Specifications

Spec Value
OEM Part Number 1172472
Type Single-Pole (1-Pole) Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Contact Rating 30 Amps
Coil Voltage 24V
Features Integrated shunt
Fits Model WJA330000K000A1

Compatibility

Engineered as a direct OEM replacement for the ICP WJA330000K000A1 and shared across the Heil, Tempstar, Comfortmaker, and Sears/Kenmore families that use this chassis. Always confirm the original part number and coil voltage before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage across the line terminals with a multimeter.
  2. Access — Remove the condenser control panel cover.
  3. Document — Photograph all line and low-voltage wiring before disconnecting anything.
  4. Remove — Label and pull the wires off the old contactor, then unscrew it from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo, matching line (L1/L2) and coil (24V) terminals.
  6. Test — Restore power and confirm the contactor pulls in on a cooling call and drops out cleanly when satisfied.

Signs You Need a Replacement

  • Compressor and fan won't start, or you hear only a hum/buzz
  • Visible pitting, burning, or melted plastic on the contacts
  • Chattering or rapid clicking from the contactor
  • Unit runs continuously and won't shut off (welded contacts)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WJA330000K000A1 — 24V Coil with Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WJA330000K000A1 — 24V Coil with Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WJA330000K000A1 — 24V Coil with Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online