Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Run Capacitor for WPG3364090LKC1 — 2.0 MFD Oval/Round | Ships Today
ICP

ICP Run Capacitor for WPG3364090LKC1 — 2.0 MFD Oval/Round | Ships Today

SKU: 1171552 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM run capacitor provides the steady phase-shifted current a single-phase motor needs to run efficiently in the WPG3364090LKC1 packaged unit. Rated at 2.0 MFD, it supports the condenser/fan motor circuit, and the kit includes both the oval clamp capacitor (1171552) and the round 2.0 MFD clamp capacitor (1095021) with mounting hardware. A weak or failed run capacitor is one of the most common HVAC failures — it causes a motor to hum but not start, run hot, or trip on overload. Capacitors degrade with heat and age, so testing the measured MFD against the rated value is the fastest diagnostic.

Specifications

Spec Value
Part Number 1171552 (oval clamp), 1095021 (round 2.0 MFD clamp)
Type Single Run Capacitor
Brand ICP (Tempstar / Heil)
Capacitance 2.0 MFD
Mounting Clamp (oval / round)

Compatibility

OEM replacement for the ICP Tempstar Heil WPG3364090LKC1 packaged gas/electric unit and ICP-family equipment using a 2.0 MFD run capacitor. Match MFD rating and case shape (oval/round) to your existing capacitor before ordering.

Installation Guide

  1. Safety First — Disconnect power, then discharge the capacitor across its terminals with an insulated resistor and verify zero voltage with a multimeter.
  2. Access — Remove the electrical-compartment service panel.
  3. Document — Photograph the terminal wiring before disconnecting.
  4. Remove — Disconnect the leads and loosen the mounting clamp to free the old capacitor.
  5. Install — Secure the new capacitor in the clamp and reconnect the leads per your photo.
  6. Test — Restore power and confirm the motor starts and runs without humming or overheating.

Signs You Need a Replacement

  • Motor hums but won't start, or starts slowly
  • Bulged, leaking, or burst capacitor case
  • Measured MFD reads well below the 2.0 rating
  • Motor overheats or trips on overload

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my ICP WPG3364090LKC1 — 2.0 MFD Oval/Round | Ships Today?
Yes. This is the factory-specified OEM capacitor for the ICP WPG3364090LKC1 — 2.0 MFD Oval/Round | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my ICP WPG3364090LKC1 — 2.0 MFD Oval/Round | Ships Today?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.