Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Run Capacitor 7.5 MFD 370V for RGS213LRCA0AAAA — Oval Single-Run | Ships Today
ICP

ICP Run Capacitor 7.5 MFD 370V for RGS213LRCA0AAAA — Oval Single-Run | Ships Today

SKU: 1176150 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM oval run capacitor rated 7.5 MFD at 370 volts (part number 1176150) for the ICP Tempstar Heil RGS213LRCA0AAAA furnace, supplied with the matching capacitor mounting plate (1183001) and oval capacitor clamp (1171552). The run capacitor provides the phase shift that keeps the motor running efficiently. A weak or failed capacitor causes hard starting, motor overheating, increased amp draw, and eventual motor failure. Replacing it restores smooth, efficient motor operation.

Specifications

Spec Value
Part Number 1176150 (cap), 1183001 (plate), 1171552 (clamp)
Capacitance 7.5 MFD
Voltage 370V
Type Single-Run, Oval
Brand ICP / Tempstar / Heil
Fit OEM Replacement

Compatibility

Direct-fit replacement for the ICP Tempstar Heil RGS213LRCA0AAAA and related RGS213 models specifying the 7.5 MFD 370V run capacitor 1176150 with plate and clamp. Confirm the MFD, voltage, and part number on your existing capacitor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, verify zero voltage, and discharge the capacitor across its terminals with an insulated resistor.
  2. Access — Remove the service panel to reach the capacitor mounting plate.
  3. Document — Photograph all terminal wiring before disconnecting.
  4. Remove — Note the lead positions, pull the terminals, and release the old capacitor from the clamp.
  5. Install — Secure the new capacitor with the included plate and clamp, then reconnect each lead per your photo.
  6. Test — Restore power and verify the motor starts cleanly with normal amp draw.

Signs You Need a Replacement

  • Motor hums but is slow to start or won't start
  • Bulged, leaking, or burst capacitor housing
  • Elevated motor amp draw or frequent overload trips
  • Measured capacitance well outside the 7.5 MFD rating

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my ICP RGS213LRCA0AAAA — Oval Single-Run | Ships Today?
Yes. This is the factory-specified OEM capacitor for the ICP RGS213LRCA0AAAA — Oval Single-Run | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my ICP RGS213LRCA0AAAA — Oval Single-Run | Ships Today?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart