Overview

This is the OEM run capacitor assembly for the ICP / Heil / Tempstar RGS213LDEA0AAAA gas furnace. The capacitor (OEM part 1176150) is a 7.5 MFD, 370-volt oval single-run unit that supplies the steady phase shift the blower motor needs to run efficiently. The kit also includes the capacitor mounting plate (1183001) and oval clamp (1171552) for a secure fit. As a run capacitor weakens, the blower draws excess amperage, runs hot, hums, or never reaches full speed — causing weak airflow and premature motor failure. Replacing a tired capacitor is the cheapest insurance for an expensive blower motor.

Specifications

Spec Value
Part Number 1176150 (plate 1183001, clamp 1171552)
Type Single Run, Oval
Brand ICP / Heil / Tempstar
Capacitance 7.5 MFD
Voltage 370V

Compatibility

Engineered for the ICP/Heil/Tempstar RGS213LDEA0AAAA furnace and shared RGS213 platform variants. Verify your existing capacitor reads 7.5 MFD at 370V before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter. Discharge the old capacitor across its terminals with an insulated resistor before touching.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph all wire positions before disconnecting.
  4. Remove — Loosen the oval clamp, slide out the old capacitor, and transfer the leads one at a time.
  5. Install — Mount the new capacitor in the plate and clamp, then reconnect the leads exactly per your photo.
  6. Test — Restore power and confirm the blower spins up to full speed without humming.

Signs You Need a Replacement

  • Blower motor hums but won't start or starts slowly
  • Bulged, leaking, or domed capacitor top
  • Weak or reduced airflow at the registers
  • Capacitor reads out of tolerance (below ~6.4 MFD) on a meter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my ICP RGS213LDEA0AAAA — Oval Single Run | Ships Today?
Yes. This is the factory-specified OEM capacitor for the ICP RGS213LDEA0AAAA — Oval Single Run | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my ICP RGS213LDEA0AAAA — Oval Single Run | Ships Today?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.