Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Run Capacitor 7.5 MFD 370V for RGS210LDEA0AAAA — OEM Oval Cap with Plate & Clamp | Ships Today
ICP

ICP Run Capacitor 7.5 MFD 370V for RGS210LDEA0AAAA — OEM Oval Cap with Plate & Clamp | Ships Today

SKU: 1176150 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM 7.5 MFD, 370V oval run capacitor (part number 1176150) for the ICP Tempstar Heil RGS210LDEA0AAAA furnace, supplied with the matching capacitor mounting plate (1183001) and oval clamp (1171552). The run capacitor provides the phase shift that keeps the blower motor running smoothly and efficiently. A weak or failed capacitor causes the motor to hum, struggle to start, overheat, or stop entirely. Replacing a drifting capacitor restores rated torque and protects the motor windings from premature failure.

Specifications

Spec Value
Part Number 1176150 (cap), 1183001 (plate), 1171552 (clamp)
Type Single Run Capacitor, Oval
Capacitance 7.5 MFD
Voltage Rating 370V
Brand ICP (Tempstar / Heil)
Fits Model RGS210LDEA0AAAA

Compatibility

Direct OEM replacement for the ICP Tempstar Heil RGS210LDEA0AAAA furnace. The included plate and clamp ensure the oval capacitor mounts securely in the original location. Verify your existing capacitor reads 7.5 MFD at 370V before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage; discharge the old capacitor across its terminals with an insulated resistor.
  2. Access — Remove the service panel to reach the capacitor and motor.
  3. Document — Photograph the terminal wiring before disconnecting.
  4. Remove — Loosen the clamp, disconnect the leads, and remove the old capacitor.
  5. Install — Mount the new capacitor with the supplied plate and clamp, then reconnect leads per your photo.
  6. Test — Restore power and confirm the blower starts and runs smoothly.

Signs You Need a Replacement

  • Blower motor hums but won't start spinning.
  • Bulged, leaking, or swollen capacitor canister.
  • Motor overheats or trips on thermal overload.
  • Measured capacitance has drifted below the 7.5 MFD rating.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my ICP RGS210LDEA0AAAA — OEM Oval Cap with Plate & Clamp | Ships Today?
Yes. This is the factory-specified OEM capacitor for the ICP RGS210LDEA0AAAA — OEM Oval Cap with Plate & Clamp | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my ICP RGS210LDEA0AAAA — OEM Oval Cap with Plate & Clamp | Ships Today?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.