Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Run Capacitor 2.0 MFD Round for WPG3244040LKC1 — With Clamp | Ships Today
ICP

ICP Run Capacitor 2.0 MFD Round for WPG3244040LKC1 — With Clamp | Ships Today

SKU: 1095021 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2.0 MFD round run capacitor (part #1095021) supplies the steady phase-shifted current a motor needs to run efficiently on the ICP/Tempstar/Heil WPG3244040LKC1 unit. It ships with the original-style round mounting clamp. A weak or failed run capacitor causes a motor to hum without starting, overheat, draw high amperage, or cycle on its thermal overload. Because capacitors degrade gradually, testing microfarad value with a meter is the only reliable diagnosis. This replacement matches the OEM 2.0 MFD rating for proper motor performance and long service life.

Specifications

Spec Value
Part Number 1095021
Type Single-Run Capacitor, Round
Brand ICP / Tempstar / Heil
Capacitance 2.0 MFD
Includes Mounting clamp
Fit OEM

Compatibility

Direct OEM replacement for the ICP, Tempstar, Heil, Comfortmaker, and Arcoaire WPG3244040LKC1 packaged unit. Confirm the MFD value stamped on your existing capacitor matches 2.0 before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter. Discharge the old capacitor across its terminals with an insulated resistor before handling.
  2. Access — Remove the service panel to reach the control area.
  3. Document — Photograph the terminal wiring before disconnecting.
  4. Remove — Loosen the clamp, pull the spade connectors, and remove the old capacitor.
  5. Install — Secure the new capacitor in the clamp and reconnect the leads per your photo.
  6. Test — Restore power and confirm the motor starts instantly and runs smoothly.

Signs You Need a Replacement

  • Motor hums but will not start spinning
  • Bulged, leaking, or visibly swollen capacitor top
  • Measured microfarad reading outside the rated 2.0 MFD tolerance
  • Motor overheats or trips on thermal overload

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my ICP WPG3244040LKC1 — With Clamp | Ships Today?
Yes. This is the factory-specified OEM capacitor for the ICP WPG3244040LKC1 — With Clamp | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my ICP WPG3244040LKC1 — With Clamp | Ships Today?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera