Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Round Run Capacitor for WPG3424090LKC1 — 2.0 MFD | Ships Today
ICP

ICP Round Run Capacitor for WPG3424090LKC1 — 2.0 MFD | Ships Today

SKU: 1095021 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2.0 MFD round run capacitor provides the steady phase shift a single-phase motor needs to run efficiently on the ICP WPG3424090LKC1 system. Run capacitors store and release energy to keep the motor's start winding energized, maintaining torque and reducing amp draw. A weak or failed 2.0 MFD capacitor causes the associated motor to hum without starting, run hot, draw high amperage, or cycle on its thermal overload. Capacitors are a common, inexpensive failure point — a bulging top, leaking oil, or an out-of-tolerance microfarad reading all signal replacement. Includes the round mounting clamp (OEM 1095021).

Specifications

Spec Value
Part Number 1095021
Type Single Run Capacitor, Round
Brand ICP / Heil / Tempstar
Capacitance 2.0 MFD
Includes Round mounting clamp
Fit OEM Replacement

Compatibility

Direct-fit OEM replacement for the ICP / Heil / Tempstar / Comfortmaker WPG3424090LKC1 unit. Fits ICP-family equipment calling for a 2.0 MFD round run capacitor. Confirm the microfarad and voltage rating stamped on your existing capacitor before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage, then discharge the capacitor across its terminals with an insulated resistor before touching it.
  2. Access — Remove the service panel to reach the capacitor and its clamp.
  3. Document — Photograph the terminal wiring before disconnecting.
  4. Remove — Pull the spade connectors, loosen the mounting clamp, and remove the old capacitor.
  5. Install — Secure the new capacitor in the clamp and reconnect the leads to the matching terminals per your photo.
  6. Test — Restore power and confirm the motor starts smoothly and runs at normal amperage.

Signs You Need a Replacement

  • Motor hums but will not start or is slow to start
  • Bulging, swollen, or leaking capacitor case
  • Microfarad reading outside ±6% of 2.0 MFD on a meter
  • Motor runs hot or trips on thermal overload

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my ICP WPG3424090LKC1 — 2.0 MFD | Ships Today?
Yes. This is the factory-specified OEM capacitor for the ICP WPG3424090LKC1 — 2.0 MFD | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my ICP WPG3424090LKC1 — 2.0 MFD | Ships Today?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online