This OEM round run capacitor (part number 1095021) is a 2 MFD, 370/440V single-run capacitor used in ICP/Tempstar/Heil condensing units and heat pumps such as the YG024GA2. A run capacitor delivers the continuous phase shift a fan or small motor needs to start and run efficiently. As the capacitor degrades, the motor draws higher current, overheats, and eventually fails to start. Typical symptoms include a condenser fan that hums without spinning, repeated overload trips, a bulged or leaking capacitor can, and weak cooling performance during peak heat.

Specifications

Spec Value
Part Number 1095021
Type Round single-run capacitor
Brand ICP (Tempstar / Heil)
Capacitance 2 MFD
Voltage 370/440V
Fit OEM direct replacement

Compatibility

Engineered as a direct OEM replacement for ICP, Tempstar, Heil, and Comfortmaker equipment using part 1095021, including model YG024GA2. Always verify the MFD and voltage rating stamped on your existing capacitor before installation.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter. Discharge the capacitor across its terminals with an insulated resistor before touching it.
  2. Access — Remove the unit service panel to expose the capacitor.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Loosen the mounting clamp/strap, pull the spade connectors, and lift out the old capacitor.
  5. Install — Mount the new 2 MFD capacitor in the clamp and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the motor starts and runs smoothly without humming or overheating.

Signs You Need a Replacement

  • Fan or motor hums but will not start
  • Bulged, swollen, or leaking capacitor housing
  • Unit intermittently trips the breaker or overload
  • Measured capacitance is more than 6% below the 2 MFD rating

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my ICP YG024GA2 — 370/440V | Ships Today?
Yes. This is the factory-specified OEM capacitor for the ICP YG024GA2 — 370/440V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my ICP YG024GA2 — 370/440V | Ships Today?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.