Overview

This is a genuine OEM round run capacitor (part number 1095021) for the ICP Tempstar Heil WPG3244060RKC1 packaged gas/electric unit. Rated at 2 MFD and supplied with a mounting clamp, this single-value capacitor provides the steady phase shift a permanent split-capacitor motor needs to run efficiently and quietly. When a run capacitor weakens or fails, the connected motor draws excess amperage, overheats, and may fail to start at all — replacing the capacitor is one of the most common and cost-effective HVAC repairs.

Specifications

Spec Value
Part Number 1095021
Type Round Single-Run Capacitor
Brand ICP (Tempstar / Heil)
Capacitance 2 MFD
Voltage Rating 440V (compatible with 370V applications)
Mounting Round can with included clamp

Compatibility

Engineered as a direct-fit replacement for the ICP / Tempstar / Heil WPG3244060RKC1 and other units in the WPG packaged equipment family that call for OEM part 1095021. Always confirm the MFD value and voltage against the capacitor or motor data tag in your unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker or disconnect, then verify zero voltage with a multimeter. Discharge the capacitor across its terminals with an insulated resistor before touching it.
  2. Access — Remove the service panel to expose the control compartment.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Loosen the mounting clamp, slide out the old capacitor, and transfer the wires one terminal at a time.
  5. Install — Secure the new capacitor in the clamp and reconnect each lead exactly per your photo.
  6. Test — Restore power and verify the motor starts smoothly and runs at rated amperage.

Signs You Need a Replacement

  • Motor hums but will not start
  • Bulging, leaking, or visibly swollen capacitor top
  • Measured capacitance reads below the 2 MFD rating
  • Frequent overload trips or high motor amp draw

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my ICP WPG3244060RKC1 — 440V | Ships Today?
Yes. This is the factory-specified OEM capacitor for the ICP WPG3244060RKC1 — 440V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my ICP WPG3244060RKC1 — 440V | Ships Today?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.