Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Round Run Capacitor 2.0 MFD for YJ024GB1 — 440V with Clamp | Ships Today
ICP

ICP Round Run Capacitor 2.0 MFD for YJ024GB1 — 440V with Clamp | Ships Today

SKU: 1095021 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ICP round run capacitor (part number 1095021) provides the steady phase shift a motor needs to run efficiently on your ICP/Tempstar/Heil YJ024GB1 system. Rated at 2.0 MFD and 440V, it ships with the mounting clamp so it can be secured cleanly inside the control box. A run capacitor stores and releases energy on each AC cycle to keep the motor windings energized at the correct phase angle; when it weakens, the motor draws excess current, runs hot, and can fail prematurely. A bulging top, leaked oil, or a reading that has drifted out of tolerance all point to a capacitor at the end of its life.

Specifications

Spec Value
Part Number 1095021
Type Round Run Capacitor (Single)
Brand ICP (Tempstar / Heil)
Capacitance 2.0 MFD
Voltage Rating 440V
Includes Mounting Clamp
Fitment OEM Replacement

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil YJ024GB1 and equivalent units in the same family that originally used part 1095021. A 440V-rated capacitor can safely replace a 370V unit of the same MFD. Verify the MFD rating stamped on your existing capacitor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and outdoor disconnect, then verify zero voltage with a multimeter. Discharge the old capacitor across its terminals with an insulated resistor before touching it.
  2. Access — Remove the control panel to reach the capacitor.
  3. Document — Photograph the wire colors on each terminal before disconnecting.
  4. Remove — Loosen the mounting clamp and pull the leads off the spade terminals.
  5. Install — Secure the new capacitor with the included clamp and reconnect each lead to the matching terminal per your photo.
  6. Test — Restore power and confirm the motor starts smoothly and runs without hesitation.

Signs You Need a Replacement

  • Bulging, domed, or leaking capacitor top
  • Motor hums but won't start, or starts slowly
  • Capacitance reads outside the rated 2.0 MFD (±6%)
  • Frequent overload trips or a motor that runs hot

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my ICP YJ024GB1 — 440V with Clamp | Ships Today?
Yes. This is the factory-specified OEM capacitor for the ICP YJ024GB1 — 440V with Clamp | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my ICP YJ024GB1 — 440V with Clamp | Ships Today?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online