This OEM 2.0 MFD round run capacitor provides the phase-shifted starting and running torque for a motor in your ICP WPG3304040LKC1 system — typically a fan or auxiliary motor. A run capacitor stores and releases electrical energy to keep the motor turning smoothly and efficiently. As capacitors age they lose capacitance (drift below the rated 2.0 MFD), bulge, or short out, which causes the motor to hum, struggle to start, overheat, or fail entirely. This listing includes the OEM round capacitor and its mounting clamp (OEM 1095021). Always discharge a capacitor with an insulated resistor before handling, and replace with the exact MFD and voltage rating to protect the motor.

Specifications

Spec Value
Part Number 1095021
Type Single Run Capacitor, Round
Brand ICP (Tempstar / Heil)
Capacitance 2.0 MFD
Mounting Round with clamp
Fit OEM Replacement

Compatibility

Fits the ICP / Tempstar / Heil WPG3304040LKC1 packaged unit and other ICP-family equipment specifying a 2.0 MFD round run capacitor. Confirm the MFD rating and voltage on your existing capacitor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect switch, then verify zero voltage with a multimeter.
  2. Access — Remove the service/electrical access panel.
  3. Document — Photograph the capacitor terminal wiring before disconnecting, then discharge the capacitor across its terminals with an insulated resistor.
  4. Remove — Disconnect the leads, loosen the mounting clamp, and remove the failed capacitor.
  5. Install — Secure the new capacitor in its clamp and reconnect the leads to match your photo.
  6. Test — Restore power and verify the motor starts and runs smoothly.

Signs You Need a Replacement

  • Motor hums but will not start or starts slowly.
  • Visibly bulged, leaking, or burst capacitor top.
  • Measured capacitance has drifted below the 2.0 MFD rating.
  • Motor overheats or trips on thermal overload.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my ICP WPG3304040LKC1 | Ships Today?
Yes. This is the factory-specified OEM capacitor for the ICP WPG3304040LKC1 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my ICP WPG3304040LKC1 | Ships Today?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.