OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM air pressure switch with tubing (part 1178417, TUBING PRESSURE SWITCH) is the direct-fit safety control for the ICP/Tempstar/Heil WPG4484115LKA1 unit. The switch is a 24V normally-open device that proves the induced-draft blower is producing adequate negative pressure before the control board allows ignition. If venting is blocked, the draft motor is weak, or the switch itself sticks, the furnace will not light or will short-cycle on a safety lockout. Replacing a faulty switch and its hose restores reliable proving of draft and safe operation.
| Spec | Value |
|---|---|
| Part Number | 1178417 |
| Type | Air Pressure Switch (with tubing) |
| Brand | ICP (Tempstar / Heil) |
| Control Voltage | 24V |
| Action | Normally Open, proves draft |
| Fit | OEM Direct Replacement |
Built for the ICP/Tempstar/Heil WPG4484115LKA1 and shared-platform furnaces using the same draft-proving control. Confirm the pressure set point on your original switch matches before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.