Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Pressure Switch with Tubing for WPG4304040LKB1 — OEM 1178417 | Ships Today
ICP

ICP Pressure Switch with Tubing for WPG4304040LKB1 — OEM 1178417 | Ships Today

SKU: 1178417 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM pressure switch with tubing (part number 1178417) is the factory replacement for the ICP / Tempstar / Heil WPG4304040LKB1. The pressure switch is a critical safety device that proves the draft inducer is moving combustion air and that the venting is clear before the control board allows the burners to light. The included tubing connects the switch to the inducer port and reads the negative pressure it generates. When the switch fails, sticks, or the tubing cracks or clogs, the furnace will not ignite, locks out, or short cycles — even when the inducer is running fine. Replacing it with the correct OEM part restores safe, reliable ignition sequencing.

Specifications

Spec Value
Part Number 1178417
Type Air-Proving Pressure Switch w/ Tubing
Brand ICP (Tempstar / Heil)
Function Combustion Air / Draft Proving
Includes Connecting Tubing
Fitment OEM Replacement

Compatibility

A direct OEM fit for the ICP / Tempstar / Heil WPG4304040LKB1 packaged gas furnace. The switch is calibrated to this model's inducer pressure specification, so it proves draft correctly without adjustment. Match the trip set point printed on your old switch before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the service panel to reach the pressure switch near the inducer assembly.
  3. Document — Photo the wiring and tubing routing before disconnecting.
  4. Remove — Slip off the tubing, disconnect the spade terminals, and unscrew the old switch.
  5. Install — Mount the new switch, route the supplied tubing to the inducer port, and reconnect the wires per your photo.
  6. Test — Restore power, call for heat, and confirm the switch closes and the burners light in proper sequence.

Signs You Need a Replacement

  • Furnace inducer runs but burners never ignite
  • Repeated pressure-switch lockout codes
  • Short cycling on the heat call
  • Cracked, brittle, or clogged sensing tubing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my ICP WPG4304040LKB1 — OEM 1178417 | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the ICP WPG4304040LKB1 — OEM 1178417 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my ICP WPG4304040LKB1 — OEM 1178417 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart