Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Pressure Switch Tubing for WPG4484130LKB1 — OEM 1178417 | Ships Today
ICP

ICP Pressure Switch Tubing for WPG4484130LKB1 — OEM 1178417 | Ships Today

SKU: WPG4484130LKB1 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM pressure switch tubing (part 1178417) is the draft-proving hose assembly for the ICP Tempstar Heil WPG4484130LKB1 furnace. The tubing connects the inducer/collector box to the pressure switch, transmitting the negative pressure that proves combustion airflow before the control board allows the igniter and gas valve to energize. Cracked, brittle, or blocked tubing prevents the switch from closing, so the furnace locks out for safety and will not heat. Replacing this inexpensive part restores reliable draft proving and clears nuisance pressure-switch faults.

Specifications

Spec Value
Part Number 1178417
Type Pressure Switch Tubing
Brand ICP / Tempstar / Heil
Function Draft / Airflow Proving
Application Gas Furnace Pressure Switch
Fitment OEM Direct Replacement

Compatibility

Designed for the ICP / Tempstar / Heil WPG4484130LKB1 furnace and other ICP-family models using tubing 1178417. Verify routing and length against your existing hose before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph how the tubing routes between the inducer/collector box and the pressure switch ports.
  4. Remove — Pull the old tubing from both barbed fittings, inspecting ports for soot or condensate.
  5. Install — Press the new tubing fully onto each fitting with no kinks or sags that could trap condensate.
  6. Test — Restore power, start a heat call, and confirm the switch closes and the furnace ignites normally.

Signs You Need a Replacement

  • Furnace locks out on a pressure-switch fault code.
  • Tubing is cracked, hardened, kinked, or filled with condensate.
  • Inducer runs but ignition never starts.
  • Intermittent no-heat that clears after the hose is reseated.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my ICP WPG4484130LKB1 — OEM 1178417 | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the ICP WPG4484130LKB1 — OEM 1178417 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my ICP WPG4484130LKB1 — OEM 1178417 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online