Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Pressure Switch Tubing for WPG4484090LKA1 — OEM Furnace Sensing Line | Ships Today
ICP

ICP Pressure Switch Tubing for WPG4484090LKA1 — OEM Furnace Sensing Line | Ships Today

SKU: 1178417 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The OEM 1178417 pressure switch tubing is the flexible sensing line that connects the inducer/collector box to the furnace pressure switch on ICP, Heil, and Tempstar equipment. This small hose carries the negative pressure signal the switch uses to confirm the inducer is moving combustion air before the control board allows ignition. When the tubing cracks, hardens, kinks, or collects condensate, the switch can no longer sense proper draft — so the furnace locks out, short cycles, or refuses to light even though the inducer runs. Replacing aged or damaged tubing restores a clean pressure signal and reliable safe-start operation.

Specifications

Spec Value
Part Number 1178417
Type Pressure Switch Sensing Tubing
Brand ICP / Heil / Tempstar
Function Draft / pressure proving
Circuit 24V safety circuit
Application Furnace / Package Unit

Compatibility

Direct OEM replacement tubing for the ICP/Heil/Tempstar WPG4484090LKA1 package unit and related ICP-family furnaces that route the pressure switch through this sensing line. Verify the routing and connection points against your existing hose before installing.

Installation Guide

  1. Safety First — Turn off electrical power and the gas supply, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower/control access panel.
  3. Document — Photograph how the tubing routes between the inducer/collector box and the pressure switch port.
  4. Remove — Pull the old tubing from both barbed fittings, inspecting the ports for soot or moisture.
  5. Install — Push the new tubing fully onto each fitting, matching the original routing with no kinks or low traps.
  6. Test — Restore power and gas, start a heat call, and confirm the switch closes and the burners light normally.

Signs You Need a Replacement

  • Furnace inducer runs but burners never ignite
  • Pressure switch lockout or fault code on the board
  • Cracked, brittle, kinked, or moisture-filled tubing
  • Intermittent short cycling on the heat call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my ICP WPG4484090LKA1 — OEM Furnace Sensing Line | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the ICP WPG4484090LKA1 — OEM Furnace Sensing Line | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my ICP WPG4484090LKA1 — OEM Furnace Sensing Line | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online