This OEM pressure switch tubing (part 1178417) is the sensing line that connects the inducer/collector box to the pressure switch on the ICP WPG4424060RKB1. The switch proves adequate draft before the gas valve and igniter are energized; if the tubing is cracked, kinked, melted, or clogged with condensate, the switch cannot read the correct negative pressure and the control board locks out ignition. Replacing aged or brittle tubing restores reliable pressure-proving and clears intermittent no-heat lockouts.

Specifications

Spec Value
Part Number 1178417
Type Pressure Switch Sensing Tubing
Brand ICP (Tempstar / Heil)
Function Draft/pressure sensing line
Material High-temp silicone/rubber hose

Compatibility

Designed for the ICP WPG4424060RKB1 packaged unit and related WPG-series equipment under the ICP, Tempstar, Heil, and Comfortmaker brands. Verify routing length and fitting size against the original line.

Installation Guide

  1. Safety First — Disconnect power, verify zero voltage with a multimeter, and shut off gas.
  2. Access — Remove the service panel to reach the pressure switch and inducer.
  3. Document — Photograph the tubing routing and port connections before removal.
  4. Remove — Slide the old tubing off the switch port and inducer/collector box fitting, clearing any condensate.
  5. Install — Route the new tubing the same path, fully seating both ends with no kinks or sags that trap water.
  6. Test — Restore power and gas, start a heat cycle, and confirm the pressure switch closes and the burners light.

Signs You Need a Replacement

  • Furnace locks out on "pressure switch open" faults
  • Cracked, brittle, or melted sensing tubing
  • Condensate or debris blocking the line
  • Intermittent no-heat with inducer running

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my ICP WPG4424060RKB1 — OEM Sensing Line | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the ICP WPG4424060RKB1 — OEM Sensing Line | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my ICP WPG4424060RKB1 — OEM Sensing Line | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.