Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Pressure Switch Tubing for WPG4244040RKA1 — OEM | Ships Today
ICP

ICP Pressure Switch Tubing for WPG4244040RKA1 — OEM | Ships Today

SKU: 1178417 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM ICP pressure switch tubing (part number 1178417) is the flexible signal line that connects the draft-proving pressure switch to the inducer assembly on your WPG4244040RKA1 packaged unit. The tube carries the negative-pressure signal the switch needs to confirm the inducer is pulling combustion gases before the control board allows ignition. When this tubing cracks, hardens, kinks, or fills with condensate, the switch can no longer sense draft accurately — so the furnace either refuses to light or short-cycles on a false open-switch fault, even when the inducer is running fine.

Specifications

Spec Value
Part Number 1178417
Description Tubing, Pressure Switch (TUBING PRESSURE SWITCH)
Type Pressure Switch Signal Tubing
Brand ICP / Tempstar / Heil
Application Furnace Draft Proving
Fitment OEM Direct Replacement

Compatibility

A direct OEM replacement for the ICP, Tempstar, Heil and Comfortmaker WPG4244040RKA1 packaged unit. Confirm the routing and length against your existing tube before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner/control service panel.
  3. Document — Photograph the tube routing and both port connections before removing.
  4. Remove — Pull the old tube off the pressure-switch port and the inducer/collector port; discard if cracked or clogged.
  5. Install — Push the new tube fully onto both ports, matching the original routing and avoiding kinks or low traps that hold condensate.
  6. Test — Restore power and confirm the furnace proves draft and ignites on a normal call for heat.

Signs You Need a Replacement

  • Furnace locks out with a pressure-switch fault while the inducer runs
  • Short-cycling or repeated ignition retries
  • Visible cracks, brittleness, or condensate trapped in the tube
  • Tube has slipped off or split at a port connection

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my ICP WPG4244040RKA1 — OEM | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the ICP WPG4244040RKA1 — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my ICP WPG4244040RKA1 — OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online