Overview

This OEM pressure switch with tubing (Part No. 1178417) is the safety device that confirms proper draft inducer airflow before the burners in your ICP WPG4424090RKA1 are allowed to fire. The switch senses negative pressure created by the inducer through its tubing; only when correct pressure is proven does it close and let the ignition sequence continue. If the venting is blocked, the inducer is weak, or the switch itself fails, it stays open and the control board locks out the furnace to prevent unsafe combustion. Replacing a faulty switch with the genuine OEM part restores the correct pressure setpoint and safe operation.

Specifications

Spec Value
Part Number 1178417
Type Air Pressure Switch with Tubing
Brand ICP
Function Draft/airflow proving safety switch
Application Gas furnace combustion safety

Compatibility

Designed for the ICP / Tempstar / Heil WPG4424090RKA1 packaged gas-electric unit and related ICP-family furnaces using this pressure switch and tubing assembly. Match the switch part number and pressure setpoint to your existing unit before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the burner/inducer compartment service panel.
  3. Document — Photograph the switch wiring and tubing routing before removal.
  4. Remove — Disconnect the electrical terminals, slip off the tubing, and unscrew the old switch.
  5. Install — Mount the new switch, reattach the tubing without kinks, and reconnect the wiring per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm the switch closes and the burners fire normally.

Signs You Need a Replacement

  • Furnace locks out and won't ignite
  • Inducer runs but burners never light
  • Control board flashes a pressure switch fault code
  • Switch fails to close with verified good draft

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my ICP WPG4424090RKA1 — OEM w/ Tubing | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the ICP WPG4424090RKA1 — OEM w/ Tubing | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my ICP WPG4424090RKA1 — OEM w/ Tubing | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online