This is a genuine OEM tubing-style air pressure switch (part number 1178417) for the ICP/Heil/Tempstar WPG4304060LKB1 packaged gas furnace. The pressure switch is a critical safety control that verifies proper combustion airflow before the ignition sequence begins. It monitors negative pressure created by the inducer (draft) motor through a small length of tubing. When adequate draft is sensed, the normally-open contacts close and allow the control board to energize the igniter and gas valve. If the switch never closes — or opens during a heating cycle — the furnace locks out to prevent unsafe operation. A failed or drifting pressure switch is one of the most common causes of a furnace that cycles, short-cycles, or refuses to ignite.

Specifications

Spec Value
Part Number 1178417
Type Tubing Pressure Switch (Air-Proving)
Brand ICP / Heil / Tempstar / Comfortmaker
Function Combustion airflow / draft proving
Contacts Single-pole, normally open
Fitment OEM exact-fit for WPG4304060LKB1

Compatibility

Designed as a direct OEM replacement for the ICP/Heil/Tempstar WPG4304060LKB1 packaged unit. This switch is also used across closely related WPG-series furnaces sharing the same inducer and venting assembly. Always confirm the part number stamped on your existing switch matches 1178417 before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the furnace control/blower access panel.
  3. Document — Photograph the wire terminals and the tubing connection before disconnecting anything.
  4. Remove — Pull the spade terminals off the old switch, detach the rubber sensing tube, and remove the mounting screws.
  5. Install — Mount the new 1178417 switch, reconnect the tubing (no kinks), and reattach the wires per your photo.
  6. Test — Restore power and start a heat call; confirm the inducer runs and the switch closes for normal ignition.

Signs You Need a Replacement

  • Furnace inducer runs but the igniter never glows
  • Repeated lockouts or flashing pressure-switch fault codes
  • Short-cycling on the heating call
  • Switch fails a continuity/closure test when draft is present

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my ICP WPG4304060LKB1 — Tubing-Style OEM 1178417 | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the ICP WPG4304060LKB1 — Tubing-Style OEM 1178417 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my ICP WPG4304060LKB1 — Tubing-Style OEM 1178417 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.