Overview

This OEM pressure switch with tubing (OEM part number 1178417) is the combustion air-proving safety on the ICP / Tempstar / Heil WPG4244060RKA1 packaged gas unit. Before the control board allows ignition, the inducer motor must pull enough draft to close this switch — proving the venting is clear and combustion airflow is adequate. If the switch fails to close, the furnace will not light; if it fails to open, the board flags an unsafe condition. The included tubing connects the switch to the inducer pressure tap. A bad switch, a cracked hose, or a blocked vent will all halt ignition.

Specifications

Spec Value
Part Number 1178417
Type Air-Proving Pressure Switch (with tubing)
Brand ICP (Tempstar / Heil / Comfortmaker)
Function Combustion draft / vent safety proving
Application Gas furnace / package unit
Fitment OEM direct replacement

Compatibility

Direct OEM fit for the ICP WPG4244060RKA1 packaged gas/electric unit and shared-platform Tempstar, Heil, and Comfortmaker WPG-series models using pressure switch 1178417. Confirm the switch's set point ("WC) matches your old part before installing.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the control/burner access panel.
  3. Document — Photograph the switch wiring and the tubing routing to the inducer tap.
  4. Remove — Pull the spade terminals, disconnect the hose, and unscrew the old switch from its bracket.
  5. Install — Mount the new switch, attach the tubing securely (no kinks), and reconnect the wires per your photo.
  6. Test — Restore power, start a heat call, and confirm the inducer proves draft and the burners light normally.

Signs You Need a Replacement

  • Inducer runs continuously but burners never ignite.
  • Furnace short-cycles or locks out on a pressure-switch fault code.
  • Cracked, brittle, or disconnected pressure tubing.
  • Switch contacts stuck open or stuck closed when tested with a meter.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my ICP WPG4244060RKA1 — Furnace Air Proving Switch | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the ICP WPG4244060RKA1 — Furnace Air Proving Switch | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my ICP WPG4244060RKA1 — Furnace Air Proving Switch | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.