OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This genuine OEM tubing pressure switch (part #1178417) is the combustion safety control for the ICP/Tempstar/Heil WPG3484115LKC1 packaged unit. It is connected by tubing to the inducer/vent system and monitors negative draft pressure. Before the control board allows the igniter and gas valve to fire, the pressure switch must prove that the inducer is running and the flue path is clear. If draft is insufficient — due to a blocked vent, condensate-clogged tube, weak inducer, or the switch itself failing — the contacts won't close and the board safely halts ignition. A faulty or stuck switch is a frequent cause of no-heat lockouts and inducer-running-but-no-ignition complaints.
| Spec | Value |
|---|---|
| Part Number | 1178417 |
| Type | Tubing Air Pressure Switch |
| Brand | ICP (Tempstar / Heil) |
| Function | Draft / Combustion Safety Proving |
| Fit | OEM Direct Replacement |
Direct OEM fit for the ICP/Tempstar/Heil WPG3484115LKC1 packaged system. This switch is calibrated for the model's specific inducer and venting; using the exact OEM part ensures the correct pressure setpoint. Confirm the tubing port orientation and setpoint match the part being replaced.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.