Overview

This genuine OEM tubing pressure switch (part number 1178417) is a safety control for the ICP / Tempstar / Heil model WPG3484090RKC1 furnace. The pressure switch confirms that the inducer draft motor is moving combustion gases properly before the control board allows the igniter and gas valve to fire. It senses negative pressure through its connected tubing and closes to prove draft. If the switch fails, sticks open, or the tubing clogs with condensate, the furnace will not ignite — a deliberate safety lockout that prevents dangerous flue-gas conditions. Replacing a faulty switch with the correct OEM part restores reliable ignition without defeating the safety circuit.

Specifications

Spec Value
Part Number 1178417
Type Tubing Pressure Switch
Brand ICP / Tempstar / Heil
Function Draft / Combustion Air Proving
Application Gas Furnace
Fitment OEM

Compatibility

A direct-fit replacement for the ICP, Tempstar, and Heil model WPG3484090RKC1 and related furnaces. Pressure switches are calibrated to a specific trip point — always match the part number and rating to your original switch before installing.

Installation Guide

  1. Safety First — Turn off the gas and disconnect electrical power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace access panel to reach the switch and inducer assembly.
  3. Document — Photograph the wire terminals and tubing connection before disconnecting.
  4. Remove — Pull the tubing off the port, disconnect the spade terminals, and remove the mounting screws.
  5. Install — Mount the new switch, reconnect the wires and tubing per your photo, and confirm the tubing has no kinks or trapped condensate.
  6. Test — Restore gas and power, call for heat, and confirm the inducer runs and the burners light.

Signs You Need a Replacement

  • Furnace inducer runs but burners never light
  • Control board flashes a pressure-switch fault code
  • Switch chatters or fails to close on a call for heat
  • Furnace short-cycles or locks out intermittently

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my ICP WPG3484090RKC1 — OEM Tubing Pressure Switch | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the ICP WPG3484090RKC1 — OEM Tubing Pressure Switch | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my ICP WPG3484090RKC1 — OEM Tubing Pressure Switch | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online