Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Pressure Switch for WPG3484090LKC1 — OEM with Tubing | Ships Today
ICP

ICP Pressure Switch for WPG3484090LKC1 — OEM with Tubing | Ships Today

SKU: 1178417 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM tubing pressure switch (part number 1178417) is the combustion safety control on your ICP/Tempstar/Heil WPG3484090LKC1 packaged gas/electric unit. It senses the negative draft created by the inducer motor through its sensing tube; once adequate airflow is proven, the switch closes and allows the control board to proceed with igniter and gas valve operation. This prevents the burners from firing without proper venting. When the switch, its tubing, or a port clogs or the diaphragm fails, the furnace stops on a pressure switch fault — the inducer runs but ignition never starts. Common causes include a cracked or blocked sensing tube, condensate-plugged ports, or a weak inducer.

Specifications

Spec Value
Part Number 1178417
Type Tubing Pressure Switch (Draft/Proving)
Brand ICP / Tempstar / Heil
Control Voltage 24V
Function Proves inducer draft before ignition

Compatibility

Direct OEM replacement for the pressure switch in the ICP/Tempstar/Heil WPG3484090LKC1 packaged gas/electric unit and compatible ICP-family equipment. Match the pressure setpoint, port count, and tubing connection to your existing switch.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the control/inducer access panel.
  3. Document — Photo the switch wiring and tubing routing before removal.
  4. Remove — Pull the spade terminals, disconnect the sensing tube, and unscrew the old switch.
  5. Install — Mount the new switch, reconnect the tubing securely with no kinks, and reattach the wiring per your photos.
  6. Test — Restore power, run a heat cycle, and confirm the switch proves draft and the unit ignites without a pressure fault.

Signs You Need a Replacement

  • Inducer runs but the furnace never ignites
  • Repeated pressure switch fault codes
  • Switch stuck open or stuck closed when tested
  • Cracked, brittle, or condensate-blocked sensing tubing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my ICP WPG3484090LKC1 — OEM with Tubing | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the ICP WPG3484090LKC1 — OEM with Tubing | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my ICP WPG3484090LKC1 — OEM with Tubing | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online