OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM tubing pressure switch (part number 1178417) is the combustion safety control on your ICP/Tempstar/Heil WPG3484090LKC1 packaged gas/electric unit. It senses the negative draft created by the inducer motor through its sensing tube; once adequate airflow is proven, the switch closes and allows the control board to proceed with igniter and gas valve operation. This prevents the burners from firing without proper venting. When the switch, its tubing, or a port clogs or the diaphragm fails, the furnace stops on a pressure switch fault — the inducer runs but ignition never starts. Common causes include a cracked or blocked sensing tube, condensate-plugged ports, or a weak inducer.
| Spec | Value |
|---|---|
| Part Number | 1178417 |
| Type | Tubing Pressure Switch (Draft/Proving) |
| Brand | ICP / Tempstar / Heil |
| Control Voltage | 24V |
| Function | Proves inducer draft before ignition |
Direct OEM replacement for the pressure switch in the ICP/Tempstar/Heil WPG3484090LKC1 packaged gas/electric unit and compatible ICP-family equipment. Match the pressure setpoint, port count, and tubing connection to your existing switch.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.