Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Pressure Switch for WPG3424090RKC1 — OEM with Tubing | Ships Today
ICP

ICP Pressure Switch for WPG3424090RKC1 — OEM with Tubing | Ships Today

SKU: 1178417 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM pressure switch (supplied with tubing) is the draft safety that verifies proper venting before the ICP Tempstar Heil WPG3424090RKC1 is allowed to fire. When the inducer motor starts, it creates a vacuum that the switch senses through its tubing; only when adequate draft is proven does the switch close and permit the control board to energize the igniter and gas valve. A failed switch, blocked tubing, or a cracked hose will prevent ignition or cause lockouts. Symptoms include the inducer running with no ignition, repeated pressure-switch fault codes, or a furnace that lights then drops out. This is an exact OEM replacement for part 1178417 and includes the connecting tubing.

Specifications

Spec Value
Part Number 1178417
Type Draft/Air Pressure Switch with Tubing
Brand ICP (Tempstar / Heil)
Function Inducer draft proving safety
Includes Connecting tubing
Fit OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP Tempstar Heil WPG3424090RKC1 packaged gas unit and ICP-family equipment (Tempstar, Heil, Comfortmaker, Arcoaire) that originally used OEM pressure switch 1178417. Match the switch set point and port configuration to your existing switch before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the control/burner compartment service panel.
  3. Document — Photograph the tubing routing and wire terminals before disconnecting.
  4. Remove — Pull the electrical leads, detach the tubing, and remove the mounting screws and old switch.
  5. Install — Mount the new switch, attach the supplied tubing (no kinks or sags), and reconnect the leads per your photo.
  6. Test — Restore power, call for heat, and confirm the inducer proves draft and the burners ignite without lockout.

Signs You Need a Replacement

  • Inducer runs but the furnace never ignites.
  • Repeated pressure-switch fault codes.
  • Furnace lights then shuts down on safety.
  • Cracked tubing or a switch stuck open/closed.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my ICP WPG3424090RKC1 — OEM with Tubing | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the ICP WPG3424090RKC1 — OEM with Tubing | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my ICP WPG3424090RKC1 — OEM with Tubing | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online