OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM pressure switch (supplied with tubing) is the draft safety that verifies proper venting before the ICP Tempstar Heil WPG3424090RKC1 is allowed to fire. When the inducer motor starts, it creates a vacuum that the switch senses through its tubing; only when adequate draft is proven does the switch close and permit the control board to energize the igniter and gas valve. A failed switch, blocked tubing, or a cracked hose will prevent ignition or cause lockouts. Symptoms include the inducer running with no ignition, repeated pressure-switch fault codes, or a furnace that lights then drops out. This is an exact OEM replacement for part 1178417 and includes the connecting tubing.
| Spec | Value |
|---|---|
| Part Number | 1178417 |
| Type | Draft/Air Pressure Switch with Tubing |
| Brand | ICP (Tempstar / Heil) |
| Function | Inducer draft proving safety |
| Includes | Connecting tubing |
| Fit | OEM Direct Replacement |
Direct-fit replacement for the ICP Tempstar Heil WPG3424090RKC1 packaged gas unit and ICP-family equipment (Tempstar, Heil, Comfortmaker, Arcoaire) that originally used OEM pressure switch 1178417. Match the switch set point and port configuration to your existing switch before ordering.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.