Overview

This genuine OEM tubing pressure switch (part number 1178417) is the safety device that confirms proper draft and venting in the ICP Tempstar Heil WPG3244060RKC1. Before the control board allows ignition, the inducer motor must pull enough negative pressure to close this switch, proving the flue is clear. If the switch cannot close — due to a blocked vent, failing inducer, or a faulty switch — the board locks out ignition to prevent unsafe operation.

Specifications

Spec Value
Part Number 1178417
Type Tubing Pressure (Draft Proving) Switch
Brand ICP (Tempstar / Heil)
Function Verifies inducer draft / venting
Application Gas furnace combustion safety

Compatibility

A direct-fit replacement for the ICP / Tempstar / Heil WPG3244060RKC1 and other units specifying OEM part 1178417. Confirm the pressure setpoint stamped on the switch matches your unit before installing.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas, then verify zero voltage with a multimeter.
  2. Access — Remove the service panel to reach the inducer and pressure switch.
  3. Document — Photograph the wire terminals and the tubing connection to the inducer port.
  4. Remove — Disconnect the wires and pressure tubing, then unscrew the old switch from its bracket.
  5. Install — Mount the new switch, reattach the tubing without kinks, and reconnect the wires per your photo.
  6. Test — Restore power and gas and confirm the switch closes and the furnace completes a normal ignition cycle.

Signs You Need a Replacement

  • Furnace locks out and will not ignite
  • Inducer runs but burners never light
  • Control board flashes a pressure-switch fault code
  • Switch fails to close with verified good draft and clear venting

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my ICP WPG3244060RKC1 — Tubing Type OEM | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the ICP WPG3244060RKC1 — Tubing Type OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my ICP WPG3244060RKC1 — Tubing Type OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.