Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Integrated Furnace Control Board Kit for RGS121HSCB0AAA — OEM | Ships Today
ICP

ICP Integrated Furnace Control Board Kit for RGS121HSCB0AAA — OEM | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part #1183618) is the integrated furnace control (IFC) brain of the ICP/Tempstar/Heil RGS121HSCB0AAA furnace. It sequences the entire heating cycle — energizing the inducer, proving the pressure switch, firing the hot surface igniter, opening the gas valve, monitoring flame, and timing the blower on and off. It also runs continuous safety logic and flashes diagnostic fault codes. When the board fails, symptoms range from no response at all to intermittent lockouts, blower that won't shut off, or erratic ignition. This kit includes the board and mounting hardware needed for a direct OEM replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Fits Model RGS121HSCB0AAA
Function Ignition, blower, inducer & safety timing control
Diagnostics LED fault-code indication

Compatibility

Built for the ICP-family RGS121HSCB0AAA and related Tempstar, Heil, and Comfortmaker furnaces using this integrated control. Because boards are revision-specific, verify part #1183618 against your existing board and unit parts list before ordering.

Installation Guide

  1. Safety First — Disconnect power to the furnace. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment panel.
  3. Document — Photograph every wire and connector on the old board; note plug locations carefully.
  4. Remove — Unplug all harnesses, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board and transfer each connector to the identical terminal per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm proper ignition, blower timing, and no fault codes.

Signs You Need a Replacement

  • Furnace completely unresponsive on a heat call
  • Repeated lockouts or erratic ignition sequencing
  • Blower runs constantly or fails to start
  • Visible burnt traces, scorched relays, or no LED activity

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS121HSCB0AAA — OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS121HSCB0AAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS121HSCB0AAA — OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online