Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Integrated Furnace Control Board for RGS244HFEA0AAAA — OEM Kit 1183618 | Ships Today
ICP

ICP Integrated Furnace Control Board for RGS244HFEA0AAAA — OEM Kit 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM Integrated Furnace Control (IFC) board kit, part number 1183618, is the electronic brain of your ICP/Heil/Tempstar RGS244HFEA0AAAA gas furnace. It manages the entire heating sequence — inducer startup, hot-surface ignition, gas valve timing, blower on/off delays, and continuous flame-sense monitoring — while running diagnostic safety checks on every cycle. When this board fails, the furnace typically will not start, locks out after a few ignition attempts, or short-cycles. A failed IFC commonly shows up as a furnace that hums but never lights, a blower that runs continuously, or an LED flashing a fault code. Operating on standard 24V control power, this factory board ships pre-flashed with the correct firmware for this model so the ignition and timing parameters match your furnace exactly.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Kit
Brand ICP / Heil / Tempstar
Control Voltage 24V
Application Gas Furnace
Fitment OEM Replacement

Compatibility

Engineered as a direct OEM replacement for the ICP/Heil/Tempstar/Comfortmaker RGS244HFEA0AAAA gas furnace. Always match the original part number on your existing board before ordering, as IFC boards are firmware-specific.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every wire and connector on the board before disconnecting anything.
  4. Remove — Unplug the molded harnesses, release the mounting screws/standoffs, and lift out the old board.
  5. Install — Mount the new board on the same standoffs and reconnect each harness exactly per your photo.
  6. Test — Restore power and run a full heat cycle; confirm clean ignition, proper blower delay, and no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • Furnace will not ignite or locks out after repeated ignition attempts
  • Blower runs continuously or fails to start after ignition
  • Diagnostic LED flashing a hard-lockout or control-fault code
  • Visible burnt traces, scorched relays, or corrosion on the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on uninstalled parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS244HFEA0AAAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS244HFEA0AAAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS244HFEA0AAAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online