Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Integrated Furnace Control Board for RGS240SEEA0AAAA — Replacement Kit | Ships Today
ICP

ICP Integrated Furnace Control Board for RGS240SEEA0AAAA — Replacement Kit | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part number 1183618) is the integrated furnace control (IFC) for the ICP/Tempstar/Heil RGS240SEEA0AAAA gas furnace. The board is the brain of the furnace — it sequences the inducer, igniter, gas valve, and blower, monitors the pressure switch and limit safeties, and reads the flame signal to confirm a clean light. When the board fails you'll see no response to a heat call, blower or inducer that won't start or won't stop, blinking diagnostic LED fault codes, or intermittent lockouts. This kit includes the replacement board so you can restore full, code-correct furnace operation and clear nuisance no-heat faults.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Line Voltage 120V
Control Voltage 24V
Fits Model RGS240SEEA0AAAA

Compatibility

Built for the ICP RGS240SEEA0AAAA and used across many ICP-family gas furnaces (Tempstar, Heil, Comfortmaker, Arcoaire). Match the existing board's part number and connector layout before ordering — this kit is a direct OEM replacement.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off gas, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment panel.
  3. Document — Photograph every harness connector and wire location on the old board before disconnecting.
  4. Remove — Unplug all connectors, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board and reconnect each harness exactly per your photos.
  6. Test — Restore power and gas, run a full heat cycle, and confirm proper sequencing with no fault codes.

Signs You Need a Replacement

  • No response to a thermostat heat call
  • Blower or inducer won't start, or won't shut off
  • Diagnostic LED flashing a hard-fault code
  • Intermittent ignition lockouts with otherwise good components

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240SEEA0AAAA — Replacement Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240SEEA0AAAA — Replacement Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240SEEA0AAAA — Replacement Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online