Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Integrated Furnace Control Board for RGS150STCA0AAAA — OEM Ignition Board | Ships Today
ICP

ICP Integrated Furnace Control Board for RGS150STCA0AAAA — OEM Ignition Board | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM integrated furnace control (IFC) board, supplied as 1183618 (KIT, CONTROL BOARD), is the electronic brain of the ICP / Tempstar / Heil RGS150STCA0AAAA gas furnace. It sequences the entire heating operation: it powers the inducer, proves the pressure switch, energizes the hot surface igniter, opens the gas valve, monitors flame via the flame sensor, and controls blower timing. A failed control board produces a wide range of symptoms — no ignition, no blower, erratic operation, or a blank diagnostic LED. This factory kit includes the board and mounting hardware for a direct replacement.

Specifications

Spec Value
OEM Part Number 1183618
Type Integrated Furnace Control Board (Kit)
Brand ICP (Tempstar / Heil / Comfortmaker)
Line Voltage 120V
Control Voltage 24V
Includes Control board + mounting kit

Compatibility

Designed for the ICP RGS150STCA0AAAA furnace and compatible ICP-family gas furnaces (Tempstar, Heil, Comfortmaker, Arcoaire, KeepRite). Match the OEM number printed on your existing board before ordering, as control boards are model-revision specific.

Installation Guide

  1. Safety First — Disconnect electrical power to the furnace and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment panel.
  3. Document — Photograph every wire and connector position on the old board before disconnecting anything.
  4. Remove — Unplug all harnesses and low-voltage terminals, remove the board mounting screws, and lift out the old control board.
  5. Install — Mount the new board, then reconnect every wire exactly per your photos, confirming firm seating on each connector.
  6. Test — Restore power and run a full heat cycle; verify the diagnostic LED shows a normal code and all components sequence correctly.

Signs You Need a Replacement

  • No diagnostic LED, or an LED showing a hard-fault flash code.
  • Furnace will not start despite a valid thermostat call.
  • Blower or inducer runs continuously or fails to engage.
  • Visible burn marks, corrosion, or cracked traces on the board.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS150STCA0AAAA — OEM Ignition Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS150STCA0AAAA — OEM Ignition Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS150STCA0AAAA — OEM Ignition Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online