Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Integrated Furnace Control Board for RGS150SFBA0AAAA — Ignition Control | Ships Today
ICP

ICP Integrated Furnace Control Board for RGS150SFBA0AAAA — Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM integrated furnace control board kit for the ICP / Heil / Tempstar RGS150SFBA0AAAA gas furnace, OEM part number 1183618. The control board is the brain of the furnace: it manages the ignition sequence, sequences the inducer and gas valve, energizes the 120V hot surface igniter, controls the blower (heat and fan), monitors safety limits and flame sense, and flashes diagnostic fault codes via its onboard LED. When the board fails, the furnace may be completely dead, stuck on continuous blower, fail to ignite, or short-cycle on false faults.

Specifications

Spec Value
OEM Part Number 1183618 (Control Board Kit)
Type Integrated Furnace Control (IFC)
Brand ICP / Heil / Tempstar
Control Voltage 24V
Line Voltage 120V
Diagnostics LED fault-code output
Fitment OEM Direct Replacement

Compatibility

Engineered for the ICP / Heil / Tempstar / Comfortmaker RGS150SFBA0AAAA gas furnace and used across compatible RGS-series and equivalent ICP-family models. Confirm your model and OEM part number against the board you are replacing before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every wire and connector on the old board, or transfer one wire at a time.
  4. Remove — Unplug all harness connectors and low-voltage leads, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board, set any DIP switches / timing jumpers to match the original, and reconnect every wire per your photo.
  6. Test — Restore power, run a full heat and fan cycle, and confirm there are no fault-code flashes.

Signs You Need a Replacement

  • Furnace completely unresponsive with no LED activity
  • Blower runs continuously or won't start
  • No ignition despite a good igniter, valve, and flame sensor
  • Repeating or erratic LED fault codes that don't clear

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS150SFBA0AAAA — Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS150SFBA0AAAA — Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS150SFBA0AAAA — Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online