Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Integrated Furnace Control Board for RGS121LECB0AAA — OEM Kit 1183618 | Ships Today
ICP

ICP Integrated Furnace Control Board for RGS121LECB0AAA — OEM Kit 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM integrated furnace control board kit (part number 1183618) for the ICP / Tempstar / Heil RGS121LECB0AAA gas furnace. The control board is the brain of the furnace — it manages the ignition sequence, monitors safety limits and flame sensing, sequences the inducer and blower motors, and controls the gas valve and hot surface igniter timing. When this board fails, the furnace may fail to ignite, short-cycle, lock out, throw error codes on its diagnostic LED, or stop responding to the thermostat entirely. Replacing it with the correct OEM kit restores proper ignition logic and safety operation. Each board ships pre-configured for this furnace family so you avoid field-programming guesswork.

Specifications

Spec Value
Part Number 1183618 (KIT CONTROL BOARD)
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil
Fits Model RGS121LECB0AAA
Control Voltage 24V / 120V
Application Gas Furnace
Fitment OEM Replacement

Compatibility

Designed as a direct OEM replacement for the ICP / Tempstar / Heil / Comfortmaker RGS121LECB0AAA gas furnace. Always confirm your existing board's part number and connector layout against PN 1183618 before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter and shut off the gas supply.
  2. Access — Remove the furnace service/blower compartment panel.
  3. Document — Photograph every wire and connector on the existing board before disconnecting anything.
  4. Remove — Unplug the wiring harnesses, release the board mounting tabs/screws, and lift out the old control board.
  5. Install — Mount the new board, then reconnect each harness exactly per your photos.
  6. Test — Restore gas and power, call for heat, and verify the full ignition sequence and blower operation; check the diagnostic LED for normal status.

Signs You Need a Replacement

  • Furnace will not ignite or fails to respond to the thermostat
  • Repeated lockouts or short-cycling on a call for heat
  • Diagnostic LED flashing a hard-fault or board fault code
  • Inducer or blower motor not sequencing correctly

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS121LECB0AAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS121LECB0AAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS121LECB0AAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online