Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Integrated Furnace Control Board for RGS102HRCA0AAA — OEM Kit | Ships Today
ICP

ICP Integrated Furnace Control Board for RGS102HRCA0AAA — OEM Kit | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ICP control board kit (part #1183618) is the integrated furnace control (IFC) that runs the entire heating sequence on the RGS102HRCA0AAA. The board manages ignition timing, gas valve sequencing, inducer and blower operation, safety lockouts, and self-diagnostics via its onboard fault LED. When the board fails — from voltage surges, corroded relays, cracked solder joints, or burned traces — the furnace may not respond to the thermostat, skip ignition, run the blower constantly, or flash error codes. Replacing the control board with the correct OEM kit restores proper sequencing and safety control.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board (Kit)
Brand ICP (Tempstar / Heil / Comfortmaker)
Control Voltage 24 VAC
Function Ignition, blower, inducer & safety control

Compatibility

Fits the ICP/Tempstar/Heil/Comfortmaker RGS102HRCA0AAA and related ICP-family furnaces specifying this control kit. Match the board's connector layout and part number to your existing control before installing.

Installation Guide

  1. Safety First — Disconnect power to the furnace; verify zero voltage with a multimeter.
  2. Access — Remove the control/blower compartment panel.
  3. Document — Photograph every connector and wire location on the old board before unplugging anything.
  4. Remove — Unplug all harness connectors, remove the mounting screws/standoffs, and lift out the old board.
  5. Install — Mount the new board and reconnect each harness to its matching terminal per your photos and the kit instructions.
  6. Test — Restore power, call for heat, and confirm a full, correct ignition and blower sequence with no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive to the thermostat.
  • Blower or inducer runs continuously or won't start.
  • Diagnostic LED flashes a hard-fault or board-failure code.
  • Visible burn marks, swollen capacitors, or scorched relays on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102HRCA0AAA — OEM Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102HRCA0AAA — OEM Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102HRCA0AAA — OEM Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online