Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Integrated Furnace Control Board for RGS090SECB0AAA — 120V Ignition Control Kit | Ships Today
ICP

ICP Integrated Furnace Control Board for RGS090SECB0AAA — 120V Ignition Control Kit | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM integrated furnace control board kit (part 1183618) is the brain of the ICP/Heil/Tempstar RGS090SECB0AAA gas furnace. It manages the ignition sequence, blower and inducer timing, safety lockouts, and diagnostic fault codes. When the board fails — often from a power surge, a blown onboard fuse, scorched relays, or cracked solder joints — the furnace may not ignite, may short-cycle, may run the blower continuously, or may flash a fault LED. This kit ships with the board and mounting hardware needed for a complete swap.

Specifications

Spec Value
Part Number 1183618 (KIT CONTROL BOARD)
Type Integrated Furnace Control Board
Brand ICP / Heil / Tempstar
Voltage 120V primary
Application Gas furnace ignition & blower control
Fits Model RGS090SECB0AAA

Compatibility

Designed for the ICP/Heil/Tempstar RGS090SECB0AAA 90,000 BTU gas furnace and matching RGS-series units using this control platform. Confirm the original board part number and connector layout against your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/service panel.
  3. Document — Photograph every wire and connector position on the old board before disconnecting anything.
  4. Remove — Unplug all harnesses, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board and transfer each connector to the matching terminal exactly per your photo.
  6. Test — Restore power, run a full heat cycle, and verify ignition, blower, and inducer operation with no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive to a heat call.
  • Continuous blower operation or erratic short-cycling.
  • Fault/diagnostic LED flashing a control-board error.
  • Visible burn marks, blown fuse, or melted relays on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS090SECB0AAA — 120V Ignition Control Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS090SECB0AAA — 120V Ignition Control Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS090SECB0AAA — 120V Ignition Control Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online