Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Ignitor Electrode for RGS303SSAA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Ignitor Electrode for RGS303SSAA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM ignitor electrode, part number 1179966, for ICP, Tempstar, and Heil gas furnaces. The electrode delivers the spark that lights the burner gas at the start of every heating cycle and, in many designs, also senses the resulting flame to confirm successful ignition. Because it sits directly in the burner flame path, the electrode tip and its ceramic insulator endure repeated thermal cycling and gradually crack, erode, or carbon-foul. When the electrode degrades you will see ignition lockouts, repeated ignition retries before the burner lights, delayed or rough light-off, or the furnace dropping out shortly after ignition because flame can no longer be sensed. Installing a fresh OEM electrode restores a strong, consistent spark and reliable flame confirmation.

Specifications

Spec Value
Part Number 1179966
Type Ignitor / Spark Electrode
Brand ICP / Tempstar / Heil OEM
Application Gas Furnace Burner Ignition
Fitment OEM Replacement

Compatibility

Built as the factory-specified ignitor electrode for the ICP Tempstar Heil RGS303SSAA0AAAA gas furnace and other ICP-family models using the same burner assembly. Confirm the bracket and electrode geometry match your existing part before installing.

Installation Guide

  1. Safety First — Shut off the gas supply, disconnect power at the breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the electrode position, gap, and wire routing before removing anything.
  4. Remove — Disconnect the ignition lead, unscrew the electrode bracket from the burner assembly, and lift it out.
  5. Install — Mount the new electrode at the same position and gap, then reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm a strong spark and stable flame on first try.

Signs You Need a Replacement

  • Furnace locks out on failed ignition
  • Multiple ignition retries before the burner lights
  • Cracked or eroded ceramic insulator at the electrode
  • Furnace drops out seconds after the burner lights (lost flame sense)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303SSAA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303SSAA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303SSAA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online