Overview

This genuine OEM ignitor electrode (part number 1179966) for ICP, Tempstar, Heil, and Comfortmaker gas furnaces delivers the spark that lights the burner at the start of every heat cycle. The electrode's ceramic insulator and precisely gapped metal tip create the high-voltage arc that ignites gas at the burner. Over time the tip erodes, cracks, or carbons over, causing failed ignition, repeated retries, or a furnace that locks out on no-flame. Because it also sits in the flame field, a degraded electrode can disrupt flame sensing and cause short-cycling. Installing a fresh OEM electrode restores fast, dependable light-off.

Specifications

Spec Value
Part Number 1179966
Type Spark Ignition Electrode
Brand ICP / Tempstar / Heil / Comfortmaker
Application Gas Furnace Burner Ignition
Fitment OEM Replacement

Compatibility

Designed for the ICP/Tempstar/Heil RGS303SEEA0AAAA gas furnace and related RGS303-series models that originally used electrode 1179966. Confirm the part number and bracket geometry against your existing electrode before ordering.

Installation Guide

  1. Safety First — Shut off the gas, disconnect power at the switch and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the electrode position, gap, and ignition wire routing before removal.
  4. Remove — Disconnect the high-voltage lead and unscrew the electrode bracket from the burner assembly.
  5. Install — Mount the new electrode at the factory gap, then reconnect the ignition wire per your photo.
  6. Test — Restore gas and power, call for heat, and confirm a strong spark and clean burner light-off.

Signs You Need a Replacement

  • Furnace clicks but the burner won't light.
  • Repeated ignition retries or hard lockout on no-flame.
  • Cracked ceramic insulator or visibly eroded electrode tip.
  • Weak, intermittent, or yellow/orange spark.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303SEEA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303SEEA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303SEEA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online