Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Ignitor Electrode for RGS303HEFA0AAAA — OEM Furnace Igniter | Ships Today
ICP

ICP Ignitor Electrode for RGS303HEFA0AAAA — OEM Furnace Igniter | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM ignitor electrode (part 1179966) for the ICP / Heil / Tempstar RGS303HEFA0AAAA gas furnace. The ignition electrode delivers the spark or ignition source that lights the burners at the start of each heat cycle. A cracked ceramic insulator, fouled tip, or incorrect gap prevents reliable ignition, causing the furnace to lock out, short-cycle, or fail to fire on a heat call. An OEM electrode guarantees the correct geometry, gap, and mounting fit so the furnace ignites cleanly every cycle.

Specifications

Spec Value
Part Number 1179966
Type Ignitor Electrode
Brand ICP / Heil / Tempstar / Comfortmaker
Application Gas Furnace Burner Ignition
Fitment Direct-fit OEM for RGS303HEFA0AAAA

Compatibility

Direct OEM replacement for the ICP-family RGS303HEFA0AAAA furnace and related Heil, Tempstar, and Comfortmaker models using the same burner ignition assembly. Verify the electrode body and bracket match your existing part before installing.

Installation Guide

  1. Safety First — Shut off the gas supply and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment access panel.
  3. Document — Photograph the electrode position, gap, and wire routing.
  4. Remove — Disconnect the ignition lead and unscrew the electrode from the burner assembly.
  5. Install — Mount the new electrode, confirm the correct gap, and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, then verify clean ignition on a heat call.

Signs You Need a Replacement

  • Furnace fails to ignite or locks out on a heat call
  • Repeated ignition retries or short-cycling
  • Cracked or chipped ceramic insulator
  • Carbon buildup or erosion on the electrode tip

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303HEFA0AAAA — OEM Furnace Igniter | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303HEFA0AAAA — OEM Furnace Igniter | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303HEFA0AAAA — OEM Furnace Igniter | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online