Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Ignitor Electrode for RGS300STFA0AAAA — Spark Ignition | Ships Today
ICP

ICP Ignitor Electrode for RGS300STFA0AAAA — Spark Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM ignitor electrode (part 1179966) for the ICP / Tempstar / Heil RGS300STFA0AAAA gas furnace. The ignitor electrode generates the high-voltage spark that lights the burner gas on each heating cycle, and on many systems the same or paired electrode also serves as the flame-sense rod confirming the burner lit. A cracked ceramic insulator, eroded electrode tip, carbon buildup, or an incorrect spark gap leads to ignition failure, delayed ignition with a rough light-off, or repeated lockouts where the furnace tries several times and then shuts down. Replacing the electrode restores a clean, consistent spark and reliable burner ignition.

Specifications

Spec Value
OEM Part Number 1179966
Type Spark ignitor electrode
Brand ICP / Tempstar / Heil
Function Direct spark burner ignition
Fit OEM direct replacement
Application Gas furnace burner

Compatibility

Direct-fit OEM replacement for the ICP / Tempstar / Heil RGS300STFA0AAAA furnace and related RGS-series units using ignitor electrode part 1179966. Confirm the part number and mounting orientation against your existing electrode before ordering.

Installation Guide

  1. Safety First — Shut off the gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the electrode position, ignition lead, and spark gap before removing anything.
  4. Remove — Disconnect the high-voltage lead and unscrew the old electrode from the burner assembly.
  5. Install — Mount the new electrode at the correct gap and orientation, then reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, then confirm a strong spark, clean light-off, and stable flame on a heat call.

Signs You Need a Replacement

  • No spark at the burner on a call for heat.
  • Delayed or rough ignition with a loud light-off.
  • Repeated ignition lockouts after several failed attempts.
  • Cracked ceramic insulator or carbon-fouled, eroded electrode tip.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS300STFA0AAAA — Spark Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS300STFA0AAAA — Spark Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS300STFA0AAAA — Spark Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online