Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Ignitor Electrode for RGS300SFAA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Ignitor Electrode for RGS300SFAA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM ignitor electrode, ICP part number 1179966, used in ICP, Tempstar, and Heil gas furnaces. The electrode delivers the high-voltage spark (or ignition reference) at the burner that lights the gas on a call for heat. A cracked ceramic insulator, eroded electrode tip, or improper gap prevents reliable ignition and is a common cause of furnace lockout, delayed ignition, or repeated retries before the burner lights. Because the electrode sits directly in the burner flame path, the ceramic and metal degrade over time and the part is considered a wear item that should be inspected during annual service.

Specifications

Spec Value
Part Number 1179966
Type Ignitor Electrode
Brand ICP (Tempstar / Heil)
Application Gas Furnace Burner Ignition
Fitment OEM Direct Replacement

Compatibility

Direct-fit OEM replacement for ICP-family furnaces including model RGS300SFAA0AAAA and related Tempstar and Heil units originally supplied with part 1179966. Confirm the bracket and gap configuration against your existing electrode before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door and any flame-shield panels.
  3. Document — Photograph the electrode position, gap, and wire routing before removal.
  4. Remove — Disconnect the high-voltage lead and unscrew the electrode bracket from the burner assembly.
  5. Install — Mount the new electrode, set the gap to spec, and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power and confirm prompt, reliable ignition on a call for heat.

Signs You Need a Replacement

  • Furnace locks out or fails to ignite on a call for heat
  • Delayed ignition with a noticeable gas smell or whoosh
  • Cracked or chipped ceramic insulator
  • Eroded or burned electrode tip / incorrect spark gap

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS300SFAA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS300SFAA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS300SFAA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online