Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Ignitor Electrode for RGS300HEAA0AGAA — Direct Spark Ignition | Ships Today
ICP

ICP Ignitor Electrode for RGS300HEAA0AGAA — Direct Spark Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM ignitor electrode (part 1179966) for the ICP RGS300HEAA0AGAA packaged gas/electric unit. On a heat call, the control board sends a high-voltage spark across this electrode to ignite the gas at the burner. The same electrode assembly typically also serves as the flame-sensing rod, confirming a flame is present so the gas valve stays open. A cracked ceramic insulator, a corroded tip, or a misaligned gap will cause ignition lockout, short-cycling on heat, or a no-heat condition. This is a low-cost, high-impact part that should be replaced at the first sign of intermittent ignition.

Specifications

Spec Value
Part Number 1179966
Type Direct spark ignitor electrode
Brand ICP
Function Spark ignition / flame sensing
Material Ceramic insulator, metal electrode rod

Compatibility

Factory replacement for the ICP / Tempstar / Heil RGS300HEAA0AGAA packaged unit. Confirm the bracket geometry and electrode orientation match your existing part before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment / service panel.
  3. Document — Photograph the ignition lead routing and the electrode position relative to the burner.
  4. Remove — Disconnect the ignition lead and remove the electrode mounting screw(s).
  5. Install — Mount the new electrode, restore the factory spark gap, and reconnect the ignition lead.
  6. Test — Restore gas and power, call for heat, and verify spark, ignition, and steady flame sensing.

Signs You Need a Replacement

  • No spark or weak spark at the burner on a heat call.
  • Ignition lockout after several failed light attempts.
  • Cracked or chipped ceramic insulator.
  • Short-cycling on heat or flame-sense faults.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS300HEAA0AGAA — Direct Spark Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS300HEAA0AGAA — Direct Spark Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS300HEAA0AGAA — Direct Spark Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.